Condensation and Mould Risk Calculator
Will a wall, window or pipe surface sweat at your room temperature and humidity? Enter the surface temperature or derive it from the U-value.
Why does condensation form on a surface?
Room air carries a certain amount of water vapour. When that air touches a surface colder than its own dew point, vapour turns to liquid: a wall sweats, a window fogs, a cold water pipe drips. Two things decide whether this happens: the dew point of the room and the temperature of the surface.
How is it worked out?
Vapour pressure and dew point are found from room temperature and relative humidity. If the surface temperature has been measured it is compared directly. If not, the internal surface temperature of an external wall is estimated from the U-value: t_s = t_i − U × R_si × (t_i − t_e), where R_si is the internal surface resistance.
A surface below the dew point has condensation. Above it, the relative humidity at the surface matters: 80 percent or more lasting for days can let mould grow.
Example
A room at 20 °C and 50 percent relative humidity, 0 °C outside. For an uninsulated wall with a U-value of 2 W/(m²·K) and a surface resistance of 0.25, the surface is at 20 − 2 × 0.25 × 20 = 10 °C. The dew point is 9.3 °C, so condensation is close but not yet present. Relative humidity at the surface is 95 percent, so mould risk is high. If room humidity rises to 52.5 percent the wall starts to sweat.
What can be done?
There are three routes: warm the surface (insulation, fixing the thermal bridge, moving furniture off the wall), lower the humidity (ventilation, fewer moisture sources) or raise the room temperature. The largest U-value shown is the insulation level needed to avoid condensation under these conditions.
Limits
This is a preliminary check of surface condensation. Interstitial condensation, two dimensional thermal bridge analysis and time dependent effects are not covered. For persistent mould and damp problems have a building physics assessment done.
Related calculators
-
HVAC and Thermodynamics
Dew Point and Relative Humidity Calculator
Find the dew point from temperature and relative humidity, or relative humidity from temperature and dew point. Absolute humidity and vapour pressure included. -
HVAC and Thermodynamics
Psychrometric Calculator: Moist Air Properties
Enter dry-bulb temperature plus relative humidity, wet bulb, dew point or humidity ratio to get enthalpy, humidity ratio, specific volume and the rest. Altitude supported. -
HVAC and Thermodynamics
Air Conditioner Cooling Load and BTU Calculator (Rough Sizing)
Rough cooling load from room area, ceiling height, occupants, equipment and glazing gains in W, kW and BTU/h. For preliminary sizing only. -
HVAC and Thermodynamics
Boiler Size Calculator (Preliminary)
Heating power from building heat loss or from area and unit load, plus instantaneous hot water power from flow rate. Rough preliminary boiler sizing.
Found a mistake or something missing?
If a value looks wrong, a size is missing or you need a feature, write to us and we will fix it.