Mass Balance
Calculate accumulation, final inventory at constant flow rates, or the composition of a mixture of two streams.
Choose a system boundary
Before writing a mass balance, decide which vessel or process section is being studied. Add every mass flow entering and leaving that boundary. If inflow exceeds outflow, mass accumulates. Starting with 200 kg, an inlet of 120 kg/h and an outlet of 100 kg/h leave 240 kg after two hours. The calculator checks whether the inventory would run out during the selected period. It cannot check overflow because vessel capacity is not an input.
Mixing calculation
For two continuous streams, total outlet flow equals their combined inlet flow. The conserved component flow is the sum of each flow multiplied by its component mass fraction. Mixing 100 kg/h at 10 percent with 300 kg/h at 30 percent gives 25 percent. This model is insufficient if there is a reaction, evaporation, an additional outlet or accumulation in the mixer.
Track the component in a separate balance
For mixing, choose the first stream as 160 kg/h at 15 % and the second as 240 kg/h at 35 %. The first carries 160 × 0.15 = 24 kg/h of component. The second carries 240 × 0.35 = 84 kg/h. Total component flow is 24 + 84 = 108 kg/h and total mixture flow is 160 + 240 = 400 kg/h. The final mass fraction is 108 / 400 = 0.27, or 27 %. Because the flows differ, a simple arithmetic average of the inlet percentages is incorrect here.
Confirm that both concentrations refer to the same component and mass basis. Do not enter volume concentration or mole fraction directly as mass percent. A pure solvent stream may have zero component percentage, but its flow still affects the total. An internal recycle that remains inside the system boundary must not be counted again as an external inlet. If flows change during the accumulation period, split the period into intervals with constant flow and use each final mass as the next initial mass. This preliminary calculation is only a mass balance. Mixture temperature, volume change, solubility and overflow safety require separate assessment.
Frequently asked questions
How do you calculate mass balance?
In this example, a tank initially holding 200 kg, with inflow 120 kg/h and outflow 100 kg/h, contains 240 kg after 2 hours. Add net flow multiplied by time to the initial mass, noting that this preliminary balance assumes constant flows and does not check overflow without tank capacity.
Related calculators
-
Fluid Mechanics
Flow Rate, Pipe Diameter and Velocity Calculator
Enter any two of flow rate, inside diameter and velocity to get the third. Q = v × A for a full circular pipe. -
Chemistry
Acid and base neutralization
Find the acid or base solution volume needed for a specified equivalence point. -
Chemistry
BOD and COD Load Calculator
Calculate pollutant mass loads from measured flow and concentration, and removal from influent and effluent loads. -
Chemistry
Carbon Emissions and Fuel CO₂ Equivalent
Estimate CO₂ equivalent from electricity or fuel use with your own emission factor, including fuel use calculated from travel distance. -
Chemistry
Chemical Equation Balancer
Balance reactions of neutral species by conserving atoms. Unique ratios are returned as the smallest positive integer coefficients. -
Chemistry
Clarifier Surface Overflow Rate
Calculate surface overflow rate from flow and effective surface area, or size the area for a specified loading rate.
Found a mistake or something missing?
If a value looks wrong, a size is missing or you need a feature, write to us and we will fix it.